Mag-Tek ® M-6 Switch element Contact . . . . . . . . . . . . Environmentally sealed Rating . . . . . . . . . . . . 4 Amps @ 120 V.A.C . . . . . . . . . . . . . 3 Amps @ 24 V.D.C Response time . . . . . . . . . 0.008 seconds Temperature . . . . . . . . . . -40 ºF to +221 ºF Pressure rating . . . . . . . . . 2000 psig Repeatability . . . . . . . . . . 0.002” (under identical operating conditions) Switch enclosure explosion proof Weld-on base plate . . . . . . . . Carbon steel Spring . . . . . . . . . . . . 316 stainless Piston . . . . . . . . . . . . 416 stainless Body assembly . . . . . . . . . 304 stainless O-Ring . . . . . . . . . . . . Viton/options Conduit opening . . . . . . . . . 1/2” N.P.T. Switch termination . . . . . . . . Labeled leads Electrical rating . . . . . . . . .  Class 1, Div 1 Group C and D, T6 Adapters to fit most switch base and mounting configurations Minimum Information Required for RFQ: 1. Quantity 2. Pipe size 3. Wall thickness 4. Contact SPDT or DPDT 5. Temperature range 6. Service (crude oil, etc.) 7. O-Ring type 8. CSA Yes No 9.  Below ground or under water Yes No * Parts included in rebuild kit. 2350 Industrial Road, Sapulpa, OK 74066 • Main: 918-445-1141 • sales@weamco.com Bulletin M6-112 Toll Free: 800-331-3790 • Fax: 918-445-4617 • www.weamco.com 5-19 Page 2 of 2 Model M-6 Sphere Detector Switch Specifications For adapters: Please contact our office for the proper dimensions sheet to verify your application. Housing Cap Screws Face Plate Electronic Element * Element O-Ring * Spring * Element O-Ring * Spring * Piston Adapter Adapter O-Rin Adapter O-Ring Base