2350 Industrial Road, Sapulpa, OK 74066 • Main: 918-445-1141 • sales@weamco.com Bulletin FH-112 Toll Free: 800-331-3790 • Fax: 918-445-4617 • www.weamco.com 5-19 Horizontal Basket Strainer TYPE FH for horizontal pipe run LINE SIZE (IN.) COMMON DIMENSIONS (IN.) APPROXIMATE OPEN AREA RATIO LINE SIZE (IN.) OD A B C D DRAIN VENT 4 10 3/4 34 52 15 16 2 1/2 1,775% 4 6 12 3/4 39 58 17 20 2 1/2 1,382% 6 8 16 47 68 18 21 2 1/2 1,176% 8 10 18 50 72 20 22 2 1/2 946% 10 12 20 58 81 22 25 2 1/2 866% 12 14 20 63 89 24 30 2 1/2 871% 14 16 24 68 96 25 34 2 1/2 817% 16 18 26 72 103 26 38 2 1/2 775% 18 20 30 75 109 29 41 2 1/2 743% 20 24 36 83 122 32 48 2 1/2 694% 24 FH A B D C OD FLOW • All dimensions are in inches and based on an ASME flanged closure • Dimensions shown are good through 600# ASME • Standard design is based on ASME B31.4 • Many quick opening closure options are available (see Bulletin OA-112) • Open area ratios are based on using a 40% open area basket media (see Bulletin AC-112) • Larger line sizes and custom designs are available Minimum Information Required for RFQ (see Strainer Bulletins SD-118 and SI-112 for assistance) 1. Quantity 2. Line size 3. ASME flange rating or beveled for welding 4. Design pressure, temperature & flow rate 5. Piping design code (ASME B31.4 is standard) 6. Basket media size (see Bulletin AC-112) 7. Housing and basket material (carbon steel is standard) 8. Other special requirements or specifications (paint, etc) FH A B D C OD FLOW